Basic requirements for design of ceramic fiber lining for refinery flame reheating furnace-2

- Jun 29, 2018-

Basic requirements for design of ceramic fiber lining for refinery flame reheating furnace-2


● The maximum distance between the anchorage zone of the hot layer and the edge of the blanket should be 76 mm.

●  When the 7.4.5 top anchor is rectangular, the spacing should not exceed the following rules: 300 mm wide blanket, 150 mm x 230 mm; 610 mm wide blanket, 230 mm x 230 mm; 910 mm wide blanket, 230 mm x 250 mm; 1220 mm wide blanket, 230 mm * 270 270.

● When the 7.4.6 wall anchor is rectangular, its spacing should not exceed the following rules: 300 mm wide blanket, 150 mm x 230 mm; 610 mm wide blanket, 230 mm x 300 mm; 1220 mm wide blanket, 270 mm x 300 mm.